fire retardant logo

Fire Retardant Coating Dallas

Hotline: 800-333-9197 8am-5pm (CST) Ph: 817-740-9197After Hours: 817-658-9197

Dallas, Fort Worth, Plano, Frisco, North Texas, Austin, Waco, Central Texas, Houston, San Antonio, Corpus Christi, South Texas, Abilene, Odessa, Midland, Lufkin,Amarillo, West Texas, Tyler, East Texas, Central Dallas, East Dallas. South Dallas, North Dallas, Dallas fire retardant coatings, Dallas flame retardant, Dallas County, Tarrant County, Dallas fire retarrdants, Dallas flame retardants, Dallas fire retardant lumber, Dallas fire retardant plywood, Dallas fire retardant timbers

INTERIOR FIRE RETARDANT
COATING or SPRAY FOR ALL WOOD PRODUCTS
PLYWOOD LUMBERTIMBER


  CLASSIFIED
19P5
FIRE RETARDANT COATING
SURFACE BURNING CHARACTERISTICS OF APPLIED COATING

Surface Douglas fir

Flame spread 35
Smoke developed 95
Number of preliminary coats None
Rate per coat (ft2/gal) --
Number of fire retardant coats 3
Rate per coat (ft2/gal) 330
Number of overcoats None
Rate per coat (ft2/gal) --
Flash point of liquid coating:  
   Fire retarding coating - closed cup, no flash


logo wood safe

TECHNICAL DATA

INTERIOR CLASS A RATING

PRODUCT DESCRIPTION:    Aqueous Based Resin

PRODUCT ANALYSIS
Total Solids
31.5%   PH
4.6 - 5.2
Weight per gallon
9.4 lbs Flash point
Non-Flammable
Specific gravity
1.104 Color
Water clear at 78°F. - Slight haze at 50°F. or lower
Volatability
Non-Volatile Solvents
Water(Contains no petroleum or derivatives of petroleum)
Anti-Fungus
excellent Resistance Bacterial
Good Resistance
Linear shrinkage
None Moisture Absorption
None
Corrosive
Mildly Toxic
None (when dry)
Insects, rodents,
aspergilli And other types of molds
Excellent resistance Termites
Excellent resistance
Preservative for wood
None Scrubability
1000 cycles

RECOMMENDED USE: Interior Class B Rating (Flame spread 35)

FLAME SAFE WOOD SAFE is a fire retardant coating. It can be used on any type of wood or porous materials, such as:

Yellow Pine Cedar Cellulose Materials
Douglas Fir Straw Wall Coverings
Redwood Blown Insulation Corrugated Board

ENVIRONMENTAL REGULATION:

This product complies will U. S. Federal Regulations concerning the use of lead in paint and hydrocarbon emissions.


QUICK REFERENCE FOR APPLYING WOOD SAFE

MATERIAL
APPLICATION
COVERAGE

Interior/exterior wood


Any type of soft woods such as:

Yellow Pine, Douglas Fir, SPF, Redwood, plywood and textured plywood

Treat before, during or after construction.

Be sure surface is clean and dry before treating.

Apply with sprayer head held at 8 to 12 inches from surface

Apply with brush or roller.

May be necessary to wipe on hardwood surfaces

Treat all surface areas where possible

Do not expose treated area to moisture for 24 hours.

Apply three (3) coats at 330 sq. ft. per gallon with the final coverage rate of 110 sq. ft. per gallon

INTERIOR/EXTERIOR:

           All surfaces to be treated must be clean and dry. Wood Safe is water-based, clear liquid that becomes insoluble when dry. Wood Safe also inhibits mold and mildew protector and repels insects. If over coating is intended, Wood Safe is an excellent primer for use under latex paints and allows a surface to be tinted witht water based stains.

DO NOT DILUTE OR MIX WOOD SAFE WITH ANY OTHER PRODUCTS.

   Avoid wasteful runs and dripping.  It should be noted that unlike some products, materials treated with Wood Safe requires no special cutting tools or special fasteners. Contact parts of any equipment should be stainless steel or plastic to prevent chemical reaction and breakdown. Storage may be done in polyethylene containers.

      Wood Safe provides a structure long term fire retardant protection.

 

stairwell

 

CAUTION:

          Product must not freeze. It must not be thinned or diluted.


OVERSPRAY:

        The overspray will not harm plants or animals. Spills can be flushed with water. A rag wetted with   bleach and water mix will clean up spotting.


CLEAN UP PROCEDURE:

          Airless Equipment.

1. Run clear water through the system until coating is flushed out. When minor sudsing on surface stops, the system is flushed.

2. Run bleach and water mix (1 part to 4 parts) through system as solvent for cleaning any residue.

            3. Repeat Step 1 if any foaming occurs in Step 2.

            4. Lubricate system as specified by equipment manufacturer to combat rusting.

If two or more applications are planned in the same day, the sprayer can be kept clean by running water through the system between applications.


          Brushes/Rollers.

              1. Clean immediately after use.

              2. Wash thoroughly with bleach and water mix (1 part to 4 parts).


SAFETY FIRST

Use approved safety devices (ropes, belts, ridge hooks, ladder, etc.) When working on steep or high areas. Take EXTREME CARE not to step on wet treated area. Surface may be slick until dry.

It is good practice to wear respirator or mask and protect hands with rubber gloves when spraying any coating or chemical. When engineered air control is not feasible, use properly maintained and properly fitted NIOSH approved respirator for solvent vapors. A dusk mask does not provide protection against vapors.

If eye contact occurs, flood with water for fifteen (15) minutes and call a physician. KEEP OUT OF REACH OF CHILDREN. DO NOT TAKE INTERNALLY.

interior wall framing

stud walls

HOME | FIRE RETARDANT COATINGS | FIRE RETARDANT WOOD | HOW IT WORKS | CONTACT US

2653 Warfield Avenue, Fort Worth, Texas 76106